Toshiba XLTR-200 Manual De Usuario

Descargar
Página de 99
 
  
70
13.7.4  Fundamental Parameters #2 
Parameter 
Function / Title 
Bank 
Mask 
Adjustment Range 
Multiplier 
0034 
BASE FREQUENCY #2 
0 / 1 
FFFF 
09C4 
∼ 9C40 (25.00 ∼ 400.00) 
0.01 
0035 
MAXIMUM OUTPUT 
VOLTAGE #2 
0 / 1 
FFFF 
0000 
∼ 0258 (0 ∼ 600) 
0036 
VOLTAGE BOOST #2 
0 / 1 
FFFF 
0000 
∼ 012C (0.0 ∼ 30.0) 
0.1 
0037 
ELECTRONIC THERMAL 
PROTECT LVL #2 
0 / 1 
00FF 
000A 
∼ 0064 (10 ∼ 100) 
0038 
STALL PROTECTION 
SELECTION #2 
0 / 1 
0040 
0000: ON 
(0) 
0040: OFF 
(1) 
 
0039 
STALL PROTECTION 
LEVEL #2 
0 / 1 
00FF 
000A 
∼ 00D7 (10 ∼ 215) 
003A 
ACCELERATION TIME #2 
0 / 1 
FFFF 
0001 
∼ EA60 (0.1~ 6000.0) 
0001 
∼ EA60 (0.01~ 600.00) 
0.1 
0.01 
003B 
DECELERATION TIME #2 
0 / 1 
FFFF 
0001 
∼ EA60 (0.1~ 6000.0) 
0001 
∼ EA60 (0.01~ 600.00) 
0.1 
0.01 
003C 
ACC/DEC PATTERN #2 
SELECTION 
0 / 1 
0030 
0000: Linear 
(0) 
0010: Self-adjusting 
(1) 
0020: S-Pattern #1 
(2) 
0030: S-Pattern #2 
(3) 
 
003D 
ACC/DEC #1/#2 SWITCH 
FREQUENCY 
0 / 1 
FFFF 
0000 
∼ Fmax 
0.01 
 
 
13.7.5  Panel Control Parameters 
Parameter 
Function / Title 
Bank 
Mask 
Adjustment Range 
Multiplier 
003E 
DIRECTION SELECTION 
(FORWARD/REV) 
0 / 1 
0004 
0000: Reverse 
(0) 
0004: Forward 
(1) 
 
003F 
STOP PATTERN 
SELECTION 
0 / 1 
0040 
0000: Decelerated stop 
(0) 
0040: Coast stop 
(1) 
 
0040 
FUNDAMENTAL PARAM 
SWITCHING 
0 / 1 
0004 
0000: V/F #1 
(1) 
0004: V/F #2 
(2) 
 
0041 
ACCEL/DECEL #1/#2 
SELECTION 
0 / 1 
0008 
0000: Accel / decel #1 
(1) 
0008: Accel / decel #2 
(2) 
 
0042 
PANEL RESET 
SELECTION 
0 / 1 
0030 
0000: All possible 
(0) 
0010: OL only 
(1) 
0020: OL, OC only 
(2) 
 
0043 
PANEL FEEDBACK 
CONTROL 
0 / 1 
0001 
0000: Feedback valid 
(0) 
0001: Feedback invalid 
(1) 
