Chapter 3  Connections and Wiring|ASDA-AB Series
 
3-16  
 
Revision March 2008, Doc. Name: 2007PDD23000011
 
3.3.2  Signals Explanation of Connector CN1 
The Tables 3.A, 3.B, & 3.C detail the three groups of signals of the CN1 interface. Table 3.A details the 
general signals. Table 3.B details the Digital Output (DO) signals and Table 3.C details the Digital Input 
(DI) signals. The General Signals are set by the factory and can not be changed, reprogrammed or 
adjusted. Both the Digital Input and Digital Output signals can be programmed by the users. 
Table 3.A General Signals 
Signal 
Pin No 
Details 
Wiring Diagram
(Refer to 3-3-3)
V_REF 42 
Motor speed command: -10V to +10V, corresponds 
to the maximum speed programmed P1-55 
Maximum Speed Limit (Factory default 3000 RPM). 
C1 
Analog 
Signal 
Input 
T_REF 18 
Motor torque command: -10V to +10V, corresponds 
to -100% to +100% rated torque command. 
C1 
Analog 
Monitor 
Output 
MON1 
MON2 
16 
15 
The MON1 and MON2 can be assigned drive and 
motor parameters that can be monitored via an 
analogue voltage. 
Please reference parameter P0-03 for monitoring 
commands and P1-04 / P1-05 for scaling factors. 
Output voltage is reference to the power ground. 
C2 
PULSE 
/PULSE 
SIGN 
/SIGN 
41 
43 
37 
36 
The drive can accept two different types of pulse 
inputs: Open Collector and Line Driver. 
Three different pulse commands can be selected via 
parameter P1-00. Quadrature , CW + CCW pulse & 
Pulse / Direction. 
C3/C4 
Position 
Pulse 
Input 
PULL HI 
35 
Should an Open Collector type of pulse be used this 
terminal must be lulled high to pin 17. 
C3 
OA 
/OA 
21 
22 
OB 
/OB 
25 
23 
Position 
Pulse 
Output 
OZ 
/OZ 
50 
24 
The motor encoder signals are available through 
these terminals. The encoder output pulse count can 
be set via parameter P1-46. 
C11/C12 
VDD 17 
VDD is the +24V source voltage provided by the 
drive. Maximum permissible current 500mA. 
Power 
COM+ 
COM- 
11 
45 
47 
49 
COM+ is the common voltage rail of the Digital Input 
and Digital Output signals. Connect VDD to COM+ 
for source mode. For external applied power sink 
mode (+12V to +24V), the positive terminal should 
be connected to COM+ and the negative to COM-. 
VCC 20 
VCC is a +12V power rail provided by the drive. It 
can be used for the input on an analog speed or 
torque command. Maximum permissible current 
100mA. 
Power 
GND 
12,13, 
19,44 
The polarity of VCC is with respect to Ground (GND).