Delta Electronics VFD-VE Series Manual De Usuario
![Delta Electronics](https://files.manualsbrain.com/attachments/17fa3c91ba74a30989b63719f51e4026476279fa/common/fit/150/50/398e3d195810ebcccb4b38ddc327372d4d2d7eb94f9ca6f971ee02d46039/brand_logo.gif)
Chapter 4 Parameters|
Revision August 2008, 03VE, SW V2.04
4-3
Pr.
Explanation
Settings
Factory
Setting
VF VFPG SVC FOCPG TQRPG
4: Stall prevention by auto accel./decel. (limited by 01-12
to 01-21)
to 01-21)
00-14
Time Unit for
Acceleration/Deceleration
and S Curve
Acceleration/Deceleration
and S Curve
0: Unit: 0.01 second
1: Unit: 0.1 second
1: Unit: 0.1 second
0
○
○
○
○
00-15 Reserved
00-16 Reserved
00-16 Reserved
00-17 Carrier Frequency
1~15KHz 10
○
○
○
○
○
00-18
Auto Voltage Regulation
(AVR) Function
(AVR) Function
0: Enable AVR
1: Disable AVR
2: Disable AVR when deceleration stop
1: Disable AVR
2: Disable AVR when deceleration stop
0
○
○
○
○
○
00-19
Auto Energy-saving
Operation
Operation
0: Disable
1: Enable
1: Enable
0
○
○
○
○
00-20
Source of the Master
Frequency Command
Frequency Command
0: Digital keypad (KPV-CE01)
1: RS-485 serial communication
2: External analog input (Pr. 03-00)
3: External UP/DOWN terminal
4: Pulse input without direction command (Pr.10-15
1: RS-485 serial communication
2: External analog input (Pr. 03-00)
3: External UP/DOWN terminal
4: Pulse input without direction command (Pr.10-15
without direction)
5: Pulse input with direction command (Pr.10-15)
0
○
○
○
○
00-21
Source of the Operation
Command
Command
0: Digital keypad (KPV-CE01)
1: External terminals. Keypad STOP disabled.
2: RS-485 serial communication (RJ-11). Keypad STOP
1: External terminals. Keypad STOP disabled.
2: RS-485 serial communication (RJ-11). Keypad STOP
disabled.
0
○
○
○
○
○
00-22 Stop Method
0: Ramp to stop
1: Coast to stop
1: Coast to stop
0
○
○
○
○
○
00-23 Reverse Operation
0: Enable reverse
1: Disable reverse
2: Disable forward
1: Disable reverse
2: Disable forward
0
○
○
○
○
○