Delta Electronics VFD-VE Series Manual De Usuario

Descargar
Página de 291
Chapter 4 Parameters|                      
Revision August 2008, 03VE, SW V2.04 
4-3
Pr. 
Explanation 
Settings 
Factory 
Setting
VF  VFPG  SVC  FOCPG  TQRPG 
4: Stall prevention by auto accel./decel. (limited by 01-12 
to 01-21) 
00-14 
Time Unit for 
Acceleration/Deceleration 
and S Curve 
0: Unit: 0.01 second 
1: Unit: 0.1 second 
 
 
00-15 Reserved 
00-16 Reserved 
00-17  Carrier Frequency 
1~15KHz 10 
 
 
00-18 
Auto Voltage Regulation 
(AVR) Function 
0: Enable AVR 
1: Disable AVR 
2: Disable AVR when deceleration stop 
 
 
00-19 
Auto Energy-saving 
Operation 
0: Disable 
1: Enable 
 
 
00-20 
Source of the Master 
Frequency Command 
0: Digital keypad (KPV-CE01) 
1: RS-485 serial communication 
2: External analog input (Pr. 03-00) 
3: External UP/DOWN terminal 
4: Pulse input without direction command (Pr.10-15 
without direction) 
5: Pulse input with direction command (Pr.10-15) 
 
 
00-21 
Source of the Operation 
Command 
0: Digital keypad (KPV-CE01) 
1: External terminals. Keypad STOP disabled. 
2: RS-485 serial communication (RJ-11). Keypad STOP 
disabled. 
 
 
00-22  Stop Method 
0: Ramp to stop 
1: Coast to stop 
 
 
00-23  Reverse Operation 
0: Enable reverse 
1: Disable reverse 
2: Disable forward