5.2 When the Emulator Debugger Does Not Start Up Properly 
(1) When the LEDs of the M34571T2-CPE Do Not Display Normally 
 
Table 5.1 Errors LEDs show and their checkpoints 1 
Error 
Connection to 
the user system
Checkpoint 
System Status POWER LED does 
not light up. 
Check that the power cable is connected. 
See “2.3 Connecting the Power Supply for the Emulator” (page 22).
 
Table 5.2 Errors LEDs show and their checkpoints 2 
Target Status LED display 
Blinking
OFF
 
POWER CLOCK  RESET 
RUN 
Connection to 
the user system
Problem & Remedy 
 
 Connected 
Check that power (Vcc) is properly supplied to the user system and 
that the user system is properly grounded. 
 
 Disconnected 
The emulator system is working properly. 
Target Status POWER LED does not light up when the user system 
is disconnected 
 
 
 
 
 
 
 
 
 
The emulator system is not working properly. 
-  Check that power is supplied to the emulator. 
-  The emulator may be damaged. Contact your local distributor. 
 
 
 
A clock is not supplied to the emulator. 
-  Check that the oscillator circuit board (OSC-2) is attached. 
-  Check that the oscillator on the oscillator circuit board (OSC-2) or 
the oscillation module is oscillating properly. 
Refer to “2.9.2 Selecting Clock Supply” (page 35) 
 
 
 
The MCU cannot be controlled. 
-  Check that the MCU is properly attached. 
-  Check that the oscillation frequency of the oscillator circuit board 
(OSC-2) is within the specified range. 
Others - 
The emulator system is not working properly. 
-  The emulator may be damaged. Contact your local distributor. 
 
 
(2) Init Dialog Box Does Not Appear at Debugger Startup 
 
Table 5.3 Checkpoints of errors at debugger startup (1/2) 
Error Checkpoint 
Communication error occurred. 
Data was not sent to the target. 
- Check the target status LED display. If the LED is blinking, the emulator did not 
start up normally. 
See “2.5.5 LED Display When the Emulator Starts Up Normally” (page 26). 
- Check that the USB cable is connected properly. 
See "2.4 Connecting the Host Machine " (page 23). 
- USB device driver has been installed before the emulator debugger start up? 
See “2.2.2 Installing the USB Device Driver” (page 21) 
Not compact emulator. 
Check that an emulator other than the compact emulator (such as PC4701, PC7501) is 
not connected.