Renesas HS2378KCM01H Manual De Usuario

Descargar
Página de 168
99
5.2
Command Descriptions
The command list of the E10A emulator is shown below.
Table 5.1   E10A HDI Commands
No
Command
Abb.
Function
1
BREAKCONDITION_
CLEAR
BCC
Clears hardware breakpoints that have been set.
2
BREAKCONDITION_
DISPLAY
BCD
Displays hardware breakpoints that have been set.
3
BREAKCONDITION_
ENABLE
BCE
Enables or disables hardware breakpoints that have
been set.
4
BREAKCONDITION_
SET
BCS
Sets hardware breakpoints.
5
BREAKPOINT
BP
Sets software breakpoints.
6
BREAKPOINT_CLEAR
BC
Clears software breakpoints that have been set.
7
BREAKPOINT_DISPLAY
BD
Displays software breakpoints that have been set.
8
BREAKPOINT_ENABLE
BE
Enables or disables software breakpoints that have
been set.
9
DEVICE_TYPE
DE
Displays MCU type currently selected.
10
GO_OPTION
GP
Sets or displays the emulation mode during user
program execution.
11
JTAG_CLOCK
JCK
Displays or sets a JTAG clock (TCK) frequency.
12
REFRESH
RF
Updates the HDI memory information to the latest
contents.
13
RESET
RE
Resets the H8S/xxxx.
14
STATUS
STS
Displays emulator status information.
15
STEP_INTERRUPT
SI
Sets or displays the enable or disable status of
interrupts during step execution.
16
TRACE_DISPLAY
TD
Displays acquired trace information.
Note: Support for these commands varies with the product.  For the specifications of each
product, refer to the on-line help.