99
5.2
Command Descriptions
The command list of the E10A emulator is shown below.
Table 5.1   E10A HDI Commands
No
Command
Abb.
Function
1
BREAKCONDITION_
CLEAR
BCC
Clears hardware breakpoints that have been set.
2
BREAKCONDITION_
DISPLAY
BCD
Displays hardware breakpoints that have been set.
3
BREAKCONDITION_
ENABLE
BCE
Enables or disables hardware breakpoints that have
been set.
4
BREAKCONDITION_
SET
BCS
Sets hardware breakpoints.
5
BREAKPOINT
BP
Sets software breakpoints.
6
BREAKPOINT_CLEAR
BC
Clears software breakpoints that have been set.
7
BREAKPOINT_DISPLAY
BD
Displays software breakpoints that have been set.
8
BREAKPOINT_ENABLE
BE
Enables or disables software breakpoints that have
been set.
9
DEVICE_TYPE
DE
Displays MCU type currently selected.
10
GO_OPTION
GP
Sets or displays the emulation mode during user
program execution.
11
JTAG_CLOCK
JCK
Displays or sets a JTAG clock (TCK) frequency.
12
REFRESH
RF
Updates the HDI memory information to the latest
contents.
13
RESET
RE
Resets the H8S/xxxx.
14
STATUS
STS
Displays emulator status information.
15
STEP_INTERRUPT
SI
Sets or displays the enable or disable status of
interrupts during step execution.
16
TRACE_DISPLAY
TD
Displays acquired trace information.
Note: Support for these commands varies with the product.  For the specifications of each