5.9.6  Setting Capture/Do not Capture Conditions 
If the selected trace mode is Fill until stop, Fill until full or Fill around TP, you can specify Capture/Do not Capture conditions. 
You can choose to extract only the necessary portions of trace information specified by events or delete the unnecessary 
portions. 
 
(1) Capture/Do not Capture conditions 
There are following types of conditions. 
 
Table 5.22 Capture/Do not Capture conditions 
Type Description 
 
Between two events 
Cycles extracted begin when a start event occurs and end 
with the next to last end event occurs (the cycle where an 
end event occurs is not extracted). 
 
Duration of an event 
Only cycles where a specified event occurred are extracted.
 
Duration of an event 
occurring in a subroutine
Only cycles where a specified event occurred in a specified 
address range (subroutine or function) are extracted. 
Extraction 
 
Instruction accessing 
specific data 
Instructions that accessed specified data are detected. 
 
Between two events 
Cycles extracted begin when a start event occurs and end 
with the next to last end event occurs (the cycle where an 
end event occurs is not extracted). 
 
Duration of an event 
Only cycles where a specified event occurred are deleted. 
Deletion 
 
Duration of an event 
occurring in a subroutine
Only cycles where a specified event occurred in a specified 
address range (subroutine or function) are deleted. 
 
Select the conditions you want to set from the list box that is displayed when you select Extract or Delete in the Record 
condition group box of the Trace conditions dialog box. 
 
 
Figure 5.54 Record condition group box 
 
 
Then click the Detail button. A page in which you can set events will be displayed.