Cisco Systems 7500 Series Manual De Usuario

Descargar
Página de 303
R E V I E W   D R A F T — C I S C O   C O N F I D E N T I A L
8-23
Cisco 7500 Series Installation and Configuration Guide
OL-5008-03 B0
Chapter 8      Troubleshooting a Cisco 7500 Series Router
  Using Cisco 7500 Series System LEDs
Using the Power Supply LEDs
This section describes the indications of the LEDs on the Cisco 7500 series power supplies.
Cisco 7505 Power Supply LED
The DC OK LED (see 
) on the interface processor end of the Cisco 7505 AC-input and 
DC-input power supplies goes on when the power supply is receiving AC or DC source power and 
providing DC power to the internal chassis components. The power supply self-monitors its own 
temperature and internal voltages. (For detailed descriptions of the show commands that display 
temperature and voltage information, see the 
.) 
Figure 8-8
Power Supply LED (AC-Input Power Supply Shown, Cisco 7505)
Cisco 7507 and Cisco 7507-MX Power Supply LEDs
There are two types of power supplies for the Cisco 7507 and Cisco 7507-MX: AC-input and DC-input. 
Each AC-input power supply has AC power and DC fail LEDs and a power switch, as shown in 
. The green AC power LED indicates that the power supply is turned on and is receiving input 
AC power. The yellow DC fail LED is normally off, but goes on if the power supply shuts down for any 
of the following reasons:   
Power supply DC section failure, which could be caused by loss of source (AC or DC) power (input 
line failure or operator turned off system power) or an actual failure in the power supply
Power supply shutdown initiated by the power supply because it detected an out-of-tolerance 
temperature or voltage condition in the power supply
In systems with a single AC-input power supply, and in systems with redundant power, when both 
AC-input power supplies are being shut down, the DC fail LED goes on momentarily as the system 
ramps down, but is off when the power supply has completely shut down. In systems with redundant 
power where one power supply is still active, the DC fail LED on the failed power supply will remain 
on (powered by the active supply).
AC receptacle
On/off switch
Cable retention 
clip
DC OK  LED
H1998