Cisco Systems 7500 Series Manual De Usuario

Descargar
Página de 303
1-51
Cisco 7500 Series Installation and Configuration Guide
OL-5008-03 B0
Chapter 1      Cisco 7500 Series Product Overview
  Fan Tray and Blower Assembly Overview
Figure 1-30
7500 Series Chassis Interface
The CI isolates the CPU and system software from chassis-specific variations, and is attached directly 
to the front (noninterface processor side) of the system backplane. 
The functions of the CI are as follows:
Report backplane type and arbiter type
Monitor power supply and fan and blower status
Monitor the temperature sensors on the RSP
Provide router power up/down control and power supply power-down control
Note
In the Cisco 7513 and Cisco 7513-MX, a hard shutdown is achieved by disabling the power source. 
In the Cisco 7576, both routers share the same power source. In the Cisco 7576, when one router 
senses a problem requiring a hard shutdown, the RSP and all interface processors installed in that 
router  (only)  are  powered  off.  In the first 14 temperature cycles, the RSP and interface processors are 
powered back on once the temperature of the system falls below a certain temperature setpoint. At 
the fifteenth temperature cycle, this temperature setpoint is changed to a very low value, preventing 
the affected router from powering back up. 
This achieves a hard shutdown of one router without affecting the other router. The RSP and interface 
processors will remain disabled until the power is manually recycled. This allows you to choose a 
suitable time to recycle the power when it will not adversely affect your users.
For CI maintenance information, see 
, an
. (For all Cisco 7500 series routers, a spare CI 
ships as Product Number MAS-7500CI=.)
Fan Tray and Blower Assembly Overview
Blower and fan tray assemblies cool the interior of the Cisco 7505 router chassis. It may be difficult to 
determine whether or not the fans or blowers are operating in noisy, air-conditioned rooms. If you 
determine that they are not operating, contact a customer service representative immediately. There are 
no installation adjustments that you should make if the fan or blower assembly does not function 
properly at initial startup. 
H2877
Chassis interface
Standoff
screw holes
Standoff
screw holes