Chapter 1      Cisco 7500 Series Product Overview
  Fan Tray and Blower Assembly Overview
Cisco 7505 Fan Tray Assembly
The Cisco 7505 uses a fan tray assembly (see 
) consisting of six fans that supply cooling air 
to the chassis interior. The assembly is accessible from behind the chassis front panel. 
Figure 1-31
Fan Tray Assembly (Cisco 7505)
All six fans should be operating whenever system power is on. The system automatically shuts down if 
any one or more of the fans is operating outside the specified range. A variable speed feature allows the 
fans to operate at a slower speed when the internal chassis temperature is within the normal operating 
range, and at a higher speed if the internal temperature exceeds a specified temperature. (A spare fan tray 
ships as Product Number MAS/5-FAN=.) For fan tray maintenance information, see the 
Cisco 7507 and Cisco 7507-MX Blower Assembly
The Cisco 7507 and Cisco 7507-MX uses a blower assembly (see 
) that supplies cooling air 
to the chassis interior. (A spare blower assembly ships as Product Number MAS-7KFAN=.) For blower 
assembly maintenance information, see the 
.