Cisco Systems Cisco 3600 Manual De Usuario

Descargar
Página de 146
3-19
Cisco 3600 Series Routers Hardware Installation Guide
OL-2056-05
Chapter 3      Installing the Router
Installing Chassis Ground Connection
Installing Chassis Ground Connection
All Cisco 3600 series router chassis require a reliable earth ground connection. You must connect the 
chassis to a reliable earth ground; the ground wire must be installed in accordance with local electrical 
safety standards.
For NEBS-compliant grounding, use size AWG 6 (13 mm
2
) wire and the ground lug provided in the 
accessory kit.
For NEC-compliant grounding, use size AWG 14 (2 mm
2
) or larger wire and an appropriate 
user-supplied ring terminal.
For EN/IEC 60950-compliant grounding, use size AWG 18 (1 mm
2
) or larger wire and an 
appropriate user-supplied ring terminal.
For chassis grounding instruction, see one of the following sections:
Cisco 3620 and Cisco 3640 Chassis Ground Connection
To connect a Cisco 3620 or Cisco 3640 chassis to ground, perform this procedure:
Step 1
Attach the ground-lug bracket to the power supply as shown in 
. Use a 
number 2 Phillips screwdriver and the screw or screws that are already in the router chassis.
For Cisco 3620 routers, use the power-supply retaining screw at the bottom of the power supply.
For Cisco 3640 routers, use the two power-supply retaining screws: one at the lower left and one at the 
upper right.
DC power supply is shown. The bracket attachment for the AC power supply and the Cisco Redundant 
Power System (RPS) is similar.
Figure 3-31 Required Ground-Lug Bracket Attachment on a Cisco 3620 Router (DC Power Supply 
Shown)
15849
Bracket
Power
supply