3-28
Cisco 3600 Series Routers Hardware Installation Guide
OL-2056-05
Chapter 3      Installing the Router
Power Connections
Depending on the type of router you are installing, see one of the following procedures:
Wiring the DC-Input Power Supply in Cisco 3620 and Cisco 3640 Routers
If your router has a DC-input power supply, follow the directions in this section for proper wiring.
DC Wiring Requirements
Cisco 3620 and Cisco 3640 routers with a DC-input power supply require copper wire for the power 
connections.
For Cisco 3640 routers, DC power connections require crimp-type ring terminals or spade terminals with 
upturned lugs.
Wiring Procedure for Nominal 48 VDC Input
To connect the router to a DC power source, perform this procedure.
Step 1
Remove power from the DC circuit. To ensure that power is removed from the DC circuit, locate the 
circuit breaker for the DC circuit, switch the circuit breaker to the OFF position, and tape the 
circuit-breaker switch in the OFF position.
Tip
Secure all power cabling when installing this unit to avoid disturbing field-wiring connections.
Step 2
For Cisco 3620 routers, strip the wires to the appropriate length for the terminal block on the power 
supply.
For Cisco 3640 routers, crimp appropriate ring terminals or spade terminals to the DC power input wires. 
Strip the wires to the appropriate length for the terminals used. The following warning applies to 
Cisco 3640 routers:
Warning
When stranded wiring is required, use approved wiring terminations, such as closed-loop or 
spade-type terminals with upturned lugs. These terminations should be the appropriate size for the 
wires and should clamp both the insulation and conductor. 
Statement 1002
Step 3
Connect the DC power input wires to the terminal block as shown in 
 or 
Table 3-1
DC Wiring Requirements for Cisco 3620 and Cisco 3640 Routers
DC Power Source
DC Input
DC Input Wire Size
Safety Ground Wire Size
Overcurrent Protection
Nominal 48 VDC
–48 to –60 VDC
1
, 4 A
1.
The input voltage tolerance limits for nominal 48-V power supplies are 38 and 72 VDC.
AWG 14 (2.0 mm
2
)
AWG 14 (2.0 mm
2
)
15  A,  maximum