Cisco Systems IPMUX-1E Manual De Usuario

Descargar
Página de 217
Appendix E  Configuration Menus 
IPmux-1/1E Installation and Operation Manual 
E-12 General 
Configuration 
 
Table E-6.  IPmux-1/1E Alarms 
Alarm ID 
Alarm Description 
Trap Sent to NMS 
Loss of Signal (LOS Physical Layer)  
Alarm LOS 
1.3.6.1.4.1.164.6.1.3.0.7 
Loss of Frame (LOF Physical Layer)  
Alarm LOF 
1.3.6.1.4.1.164.6.1.3.0.8 
Alarm Indication Signal Received (AIS 
Line Physical Layer)  
Alarm AIS 
1.3.6.1.4.1.164.6.1.3.0.10 
Remote Defect Indication Received (RDI 
Line Physical Layer)  
Alarm RDI 
1.3.6.1.4.1.164.6.1.3.0.11 
21 
Far End Block Error (FEBE Line Layer)  
Alarm FEBE 
1.3.6.1.4.1.164.6.1.3.0.12 
26 
Connectivity Status 
Conn Status Trap 
1.3.6.1.4.1.164.6.1.3.0. 15 
 
The other alarms are not used.  
 
Telnet Access 
It is possible to manage the IPmux-1/1E inband via remote ASCII Terminal using 
the Telnet IP protocol. 
 
To configure Telnet Access: 
•  Select: 
 
Enable
 –Telnet is enabled 
 
Disable
 – Telnet is disabled 
 
Managers
 – Telnet is enabled only when the Managers List contains the IP 
and VLAN of the computer that opens the Telnet session (see 
Appendix B
). 
ASCII Terminal Configuration 
ASCII TERMINAL CONFIGURATION 
1. Display Mode        Color 
2. Baud Rate (bps)     19200  
3. Change Password 
4. 15 Min. Timeout     On 
 
ESC. Exit 
NOTICE:  Change the Baud Rate of the ASCII terminal after 
changing and saving of new Baud Rate data ! 
Select item from the menu:_ 
Use <Esc> key or keys <1> to <4> 
Figure E-16.  ASCII Terminal Configuration Menu 
Main Menu 
↓ 
2. Configuration 
  
1. General 
Configuration 
 
3. ASCII 
Terminal Config
Note 
Main Menu 
↓ 
2. Configuration 
 
1. General 
Configuration 
 
2. Management 
Configuration 
↓ 
4. Telnet Access