Cisco Systems ASR 1000 Series Manual De Usuario

Descargar
Página de 292
A-4
Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation and Initial Configuration Guide
OL-13208-03
Appendix A      Cisco ASR 1000 Series Routers Specifications
  Cisco ASR 1006 Router Specifications
Cisco ASR 1006 Router Auxiliary Port Signals and Pinouts
 lists the pinouts of the dual RJ-45 ports for the auxiliary port signals.
Cisco ASR 1006 Router DB-25 Pinout Assignments for Alarm Relays
The alarm ports for the Cisco ASR 1006 Router (and Cisco ASR 1004 Router) power supplies reside on 
the DB-25 connector on the face of the power supply. The alarm ports are relay contact closures that the 
IOS environmental software controls. The environmental monitoring functions of the system can include 
voltage and temperature monitoring for the router installed components and failure sensing for power 
supply fan tray.
Any alarms that light the front panel LEDs on the Cisco ASR1000-RP1 causes a contact closure between 
the corresponding pins within the DB-25 alarm port of both power supplies. In the DB-25 connector, 
each alarm consists of a three-pin set containing a common pin, a normally open pin, and a normally 
closed pin. The connections that describe alarm activity are Alarm off (Common is connected to 
normally closed and normally open is disconnected) and Alarm on (Common is connected to normally 
open and normally closed is disconnected).
 lists the common, normally open, and normally closed relay contacts accessible to an external 
alarm monitoring facility by means of the DB-25 connector. 
Table A-6
Auxiliary Port Pinouts  for Cisco ASR 1006 Router
Pin
Signal
Direction
Description
1
RTS
Out
Request to Send
2
DTR
Out
Data Terminal Ready (always On)
3
TXD
Out
Transmit Data
4
RI
Ring Indicator 
5
GND
6
RXD
In
Receive Data
7
DSR/DCD
In
Data Set Ready/Data Carrier Detect
8
CTS
In
Clear to Send
Table A-7
Cisco ASR 1006 Router DB-25 Alarm Connector Pinout Assignments 
 Signal
Description
Common
(CM)
Normally 
Open (NO)
Normally 
Closed (NC)
SPARE
CRTAA
Critical Audible Alarm 
2
1
14
MAJAA
Major Audible Alarm
16
3
15
MINAA
Minor Audible Alarm
5
4
17
CRTVA
Critical Visual Alarm
19
6
18
MAJVA
Major Visual Alarm
8
7
20
MINVA
Minor Visual Alarm
9
SPARE
SPARE—unused pin 
reserved for future use
10, 11, 12, 13