  Cisco ASR 1000 Series Router Power Supplies
DC Power Supply LEDs and Connectors for Cisco ASR 1006
This section provides information about the DC power supplies on the rear of the Cisco ASR 1006 
Router. The maximum branch circuit for the DC power supply module is 60A and the minimum is 50A. 
The DC power supply operates within specification from –48 VDC to –60 VDC continuously. The Cisco 
ASR 1006 Router has two of the same type power supplies in power supply slot 0 and power supply 
slot 1. The power supply slot numbers are on the left side of the chassis and the power supplies are 
located on the floor of the chassis.
The DC input connector is a terminal block style that supports a AWG #6 wire. The terminal block is 
compliant to all safety agencies and electrical requirements of the supply. Use the tie wraps to dress the 
input cable wires. There are three tie wrap tabs on the power supply.
The terminal block accepts two double-hole lugs, one for –48V input and another for –48V RTN. A 
plastic cover fits over the terminal block to prevent accidental contact. See 
Note
The studs on the terminal block are similar to the safety ground device on the side of the Cisco ASR 1006 
Router. For information on the safety ground lug on the side of the chassis.
The unit requires a power switch circuit breaker to serve as the main disconnect for the DC input to the 
power supply. The circuit breaker meets international safety requirements and supports 80 VDC and has 
a current rating of 50 A. The power supply unit is secured into the system chassis with four captive 
screws mounted on the faceplate. 
 shows the DC power supplies at the rear of the Cisco ASR 1006 Router. The Cisco ASR 
1006 Router supports up to two power supplies. The power supply LEDs and connectors on the rear of 
the chassis are described in the 
.
FAN OK
Bi-color LED indicates 
fan status
Green
LED illuminates green when all fans are operational. 
Red
The LED illuminates red when a fan failure is detected.
OUTPUT FAIL
Power supply activity
Red
LED is red and turned off to signal that the DC output 
voltages are within the normal operating range; output 
voltage between the minimum and maximum limits will 
not create an output fail alarm, and output voltages below 
the minimum or above the maximum will create an output 
fail alarm. 
When you turn the power supply on, the red LED is 
illuminated for two to three seconds for testing LED 
operation before going off. 