Cisco Systems OL-7396-01 Manual De Usuario

Descargar
Página de 934
9-29
ATM Switch Router Software Configuration Guide
OL-7396-01
Chapter 9
Configuring Resource Management
Configuring Physical and Logical Interface Parameters
Configuring the Interface Maximum of Individual Traffic Parameters
When a VCC is set up, you can specify per-flow (receive and transmit traffic) parameters. Traffic 
parameter limits may be configured independently by service category and traffic direction for the 
following:
Maximum peak cell rate (PCR)
Maximum sustained cell rate (SCR)
Maximum cell delay variation tolerance (CDVT)
Maximum burst size (MBS)
Maximum minimum cell rate (MCR)
To configure the traffic parameters, perform the following tasks, beginning in global configuration 
mode:
Note
These commands affect subsequent connections but not connections that are already established.
Examples
The following example shows how to configure the maximum PCR for constant bit rate (CBR) 
connections on interface 3/0/0, specified in receive mode, to 100,000 kbps:
Switch(config)# interface atm 3/0/0
Switch(config-if)# atm cac max-peak-cell-rate cbr receive 100000
The following example shows how to configure the maximum SCR for connections on interface 3/0/0, 
specified in receive mode, to 60,000 kbps:
Switch(config)# interface atm 3/0/0
Switch(config-if)# atm cac max-sustained-cell-rate receive 60000
The following example shows how to configure the maximum tolerance for CBR connections on 
interface 3/0/0, specified in receive mode, 75,000 kbps:
Command
Purpose
Step 1
Switch(config)# interface atm 
card/subcard/port[.vpt#]
Switch(config-if)# 
Selects the interface to be configured.
Step 2
Switch(config-if)# atm cac max-peak-cell-rate 
{cbr vbr | abr | ubr} {receive | transmit} rate
Configures the connection maximum PCR.
Step 3
Switch(config-if)# atm cac 
max-sustained-cell-rate 
{receive | transmit} 
rate
Configures the connection SCR.
Step 4
Switch(config-if)# atm cac max-cdvt {abr | cbr | 
ubr 
vbr} {receive | transmit} cell-count
Configures the connection maximum CDVT.
Step 5
Switch(config-if)# atm cac max-mbs {receive | 
transmit} cell-count
Configures the connection maximum MBS.
Step 6
Switch(config-if)# atm cac max-min-cell-rate 
{abr | ubr} {receive | transmit} rate
Configures the connection maximum MCR per 
service category flow.