Cisco Systems 9000 Manual De Usuario

Descargar
Página de 282
 
1-48
Cisco ASR 9000 Series Aggregation Services Router Hardware Installation Guide
Chapter 1      Preparing for Installation
Site Requirement Guidelines
 shows the lug type required for DC input cable connections.
Figure 1-52
Typical DC Power Cable Lug
 shows typical DC power source cable connections for a version 1 single DC power 
module, in this case, a module installed in slot M2 of the power tray. 
 shows typical DC power source cable connections for a version 2 single DC power 
module, in this case, a module installed in slot M3 of the power tray.
 shows the plastic safety cover for the version 2 and version 3 DC power tray connection 
terminals. 
 shows typical DC power source cable connections for a version 3 single DC power 
module, in this case, a module installed in slot M3 of the power tray.
Note
The DC power trays and power modules for the Cisco ASR 9000 Series Routers are identical, so the 
examples shown in 
 apply to all of these routers.
90 degrees +/- 5 degrees
.25 in +/- .04 in
(6.35 mm +/- 1.016 mm)
0.48 in +/- .04 in
(12.192 mm +/- 1.016 mm)
0.08 in +/- .01 in
(2.032 mm +/- 0.254 mm)
1.25 in +/- .04 in
(31.75 mm +/- 1.016 mm)
0.81 in +/- .04 in
(20.574 mm +/- 1.016 mm)
1.16 in
(29.464 mm)
1.66 in (42.164 mm )
0.63 in +/- .02 in
(16 mm +/- 0.508 mm)
0.22 in
(5.588 mm)
0.31 in
(7.874 mm)
0.27 in +/- .02 in
(6.858 mm +/- .508 mm)
Beveled wire entry
243275