Cisco Systems 9000 Manual De Usuario

Descargar
Página de 282
 
1-58
Cisco ASR 9000 Series Aggregation Services Router Hardware Installation Guide
Chapter 1      Preparing for Installation
RSP and RP Port Connection Guidelines
Figure 1-62
RSP/RP Management LAN Port LED Indicators 
Management LAN RJ-45 Cabling
When connecting the RJ-45 port to a hub, repeater, or switch, use the straight-through cable pinout as 
shown in 
Note
To comply with the intrabuilding lightning surge requirements of Telecordia GR-1089-CORE, Issue II, 
Revision 01, February 1999, you must use a shielded cable when connecting to the management LAN 
ports on the RSP/RP card. The shielded cable is terminated by shielded connectors on both ends, with 
the cable shield material tied to both connectors.
Figure 1-63
Straight-Through Cable Pinout to a Hub, Repeater or Switch
When connecting the RJ-45 port to a router, use the crossover cable pinout as shown in 
Figure 1-64
Crossover Cable Pinout Between RSPs/RPs
243165
MDI-X wiring
MDI wiring
1 TxD+
2 TxD–
3 RxD+
6 RxD–
1 RxD+
2 RxD–
3 TxD+
6 TxD–
H11007
PRP
1 TxD+
2 TxD–
3 RxD+
6 RxD–
1 TxD+
2 TxD–
3 RxD+
6 RxD–
754
3
1
PRP