Cisco Systems 1500 Manual De Usuario

Descargar
Página de 18
Chapter 5
Connecting Optical Cables
Connecting BSMs with MUX and DMX Modules
5-4
Cisco Metro 1500 Series Hardware Installation Guide
78-10588-03
Connecting BSMs with MUX and DMX Modules
To connect a BSM to MUX and DMX modules, follow these steps:
Step 1
Remove the dust cover from one end of a jumper and the blind plug from the MUX
connector labeled M1. (Use M1 if you are routing the MUX of the primary
chassis.) Connect the MiniSC plug to the open connector.
Step 2
Remove the dust cover from the other end of the jumper and the blind plug from
the BSM connector labeled M1. (Use M1 if you are routing the MUX of the
primary chassis.) Connect the MiniSC plug to the open connector of the BSM, as
shown in Figure 5-2.
Figure 5-2
Connecting a BSM to a MUX
Step 3
Remove the dust cover from one end of a jumper and the blind plug from the DMX
connector labeled D1. (Use D1 if you are routing the DMX of the primary
chassis.) Connect the MiniSC plug to the open connector.
1-8(32)
MUX
8
M1
nc
8
6
4
2
BSM
M1
D1
M2
D2
M3
D3
M4
D
4
M
D
39345
M1
M1
nc