Chapter 3 Creating and Editing Screens 
 
 
Designate Recipe Group Number 
Bits 8 to Bit 15 designate the recipe group number. When the recipe group number is 
designated and turn ON this control flag, HMI will change the value of RCPG and 
change the recipe group number automatically.   
For example (refer to Table 3-4-1), if set D5 to 520 or set$20.3 and $20.9 to 1 
simultaneously, the recipe group number will become 2 (RCPG=2). When D5 = 520, it 
indicates that Bit 3 and Bit 9 of D5 are both 1(0000 0010 0000 1000). 
For more detailed settings, please refer to the following descriptions. 
How to designate recipe group number: 
D5 = 520(0000 0010 0000 1000) 
High Byte 
(Recipe Group Designation Register) 
0000 0010 
Low Byte 
(Other control flags relevant to Recipe) 
0000 1000 
If dividing D5 into high byte and low byte, it is easily to see that high byte determines 
the recipe group number (regardless of low byte). When the high byte setting is set to 
0000 0010, it indicates that the designated group number is the 2nd group. If the 
high byte setting is changed to 0000 0011, it indicates that the designated group 
number is changed to 3rd group and vise versa.   
Recipe Number Designation Register (RBIR) 
This register is used to specify the recipe. When this flag is turned ON, the system will write 
the designated recipe group number into Recipe Number Designation Register (RBIR). After 
Change Recipe Number Flag is turned ON, HMI will change the value of RCPNO and change 
the recipe number as well.   
For example (refer to Table 3-4-1), if set D6 to 3 and set D5 or $20.0 to 1 at the same time, 
the recipe number will become 3 (RCPNO=3) When D6 is set to 3, it indicates that the 
designated recipe number is 3. When D5 = 1, it indicates that Bit 0 of D5 is 1(0000 0000 
0000 0001). 
System Control Flag Register 
Bit 
Binary Display of Relative 
Position (x) 
Function 
0-7 0000 
0000 
xxxx 
xxxx 
Multi-language Setting Value 
0000 000x 0000 0000 
Printer Flag 
0000 00x0 0000 0000 
Printer Form Feed Flag 
10-15 
xxxx xx00 0000 0000 
Reserved 
 
 
3-34 