Chapter 3 Creating and Editing Screens 
 
 
Printer Flag 
When this flag is turned ON, the current display (Hard Copy) or the editing screen can 
be printed out. When this flag is turned OFF, the printer function is disabled.   
For example (refer to Table 3-4-1), if D7 is set to 256 or set $22.8 to 1, HMI will 
perform printing function. When D7 = 256, it indicates that Bit 8 of D7 is 1(0000 0001 
0000 0000). 
 
Printer Form Feed Flag 
When this flag is turned ON, the printer will retract the paper and align the paper for 
the next run automatically. When this flag is set to OFF, the printer form feed function 
is disabled.   
For example (refer to Table 3-4-1), if D7 is set to 512 or set $22.9 to 1, HMI will retract 
the paper and align the paper for the next run automatically. When D7 = 512, it 
indicates that Bit 9 of D7 is 1(0000 0010 0000 0000). 
 
3.4.2 Status 
Block 
The status block is the way a PLC is used to get feedback from the HMI. Through the settings 
set in the registers, the controller which is connected to HMI can know HMI internal operation, 
i.e. screen switch, backlight on and off, current priority, curve sampling data and clear flag, 
etc. information. The status block consists of 8 continuous words and this cannot be changed 
(Fig. 3-4-2) When the user set the address in Status Block, PLC can read the status of DOP-B 
series HMI. Please note that when the function Control Block is disabled, the function of 
Status Block is disabled as well. In addition, ensure that the addresses of Control Block and 
Start Block must be different. 
The function and explanation of each WORD is listed as Table 3-4-2 below. In the following 
table, in the following example 1 we assume that the user uses a Delta PLC, so the available 
starting addresses in status block are Dm ~ Dm+7 (D10 ~ D17). In the following example 2, 
we assume that the user uses HMI internal register $, so the available starting address in 
control block is$m ~ $m+7 ($25 ~ $32). The user can choose if the status block designations 
are stored in PLC or HMI. 
Example 1 
(PLC register) 
Example 2 
(HMI register) 
Word 
Control Register 
Address  Example  Address  Example 
General Control Status Register (GCSR) 
Dm 
D10 
$m 
$25 
Screen Number Status Register (SNSR) 
Dm+1 
D11  
 
$m+1 
$26 
Curve Control Status Register (CCSR) 
Dm+2 
D12 
$m+2 
$27 
Sampling History Buffer Status Register (HSSR) 
Dm+3 
D13 
$m+3 
$28 
Clearing History Buffer Status Register (HCSR) 
Dm+4 
D14 
$m+4 
$29 
Recipe Status Register (RESR) 
Dm+5 
D15 
$m+5 
$30 
Recipe Number Status Register (RBSR) 
Dm+6 
D16 
$m+6 
$31 
3-36 
Revision May, 2010