ROUBLESHOOTING
System-level 
Troubleshooting
For each symptom listed in 
, perform the suggested actions in the 
order listed.
WARNING: Before you remove any component, shut down the system 
software and then turn off the power to the chassis by removing the 
chassis power cord. If the system has two power supplies, remove both 
power cords.
Table 78   Troubleshooting Actions
Symptom
Possible Cause
Suggested Action
Date/time display 
on telephones is 
wrong, either 
incorrect date or 
shows random 
characters.
A power surge has 
corrupted the system 
time.
If the display shows incorrect date, use 
NBX NetSet to reset the system time. If the 
display shows random characters, for 
example, 00; 0 #, you must:
Disconnect power to the chassis that 
holds the Call Processor.
Wait 60 seconds.
Reconnect power to the system.
Use NBX NetSet to enter the correct 
date and time.
Problem with 
Network Call 
Processor battery. 
Contact your 3Com NBX Voice - 
Authorized Partner. 
Your browser 
cannot find NBX 
NetSet.
No IP connectivity
Verify that the computer you are using to 
run the browser has network connectivity. 
See “Establishing IP Connectivity” in the 
NBX Installation Guide.
Routing problems
If your local IP environment includes a 
proxy server, you might need to 
reconfigure your browser parameters to 
ignore the proxy server. See the Help for 
your browser.