Gateway 9315 Manual De Usuario

Descargar
Página de 168
116
www.gateway.com
EF
O
O
O
G
Read  error  occurred  on  media.  Jump  back  to  checkpoint  EB.
F0
R
R
R
R
Search  for  pre-defined  recovery  file  name  in  root  directory.
F1
R
R
R
O
Recovery  file  not  found.
F2
R
R
O
R
Start reading FAT table and analyze FAT to find the clusters 
occupied by the recovery file.
F3
R
R
O
O
Start reading the recovery file cluster by cluster.
F5
R
O
R
O
Disable L1 cache.
FA
O
R
O
R
Check the validity of the recovery file configuration to the current 
configuration of the flash part.
FB
O
R
O
O
Make flash write-enabled through chipset and OEM-specific 
method. Detect correct flash part. Verify that the found flash part 
size equals the recovery file size.
F4
R
O
R
R
The recovery file size does not equal the found flash part size.
FC
O
O
R
R
Erase the flash part.
FD
O
O
R
O
Program the flash part.
FF
O
O
O
O
The  flash  has  been  updated  successfully.  Make  flash 
write-disabled. Disable ATAPI hardware. Restore CPUID value 
back into register. Give control to F000 ROM at F000:FFF0h.
Check 
point
Diagnostic LED decoder
G=Green, R=Red, O=Orange
Description