Gateway 9315 사용자 설명서
116
www.gateway.com
EF
O
O
O
G
Read error occurred on media. Jump back to checkpoint EB.
F0
R
R
R
R
Search for pre-defined recovery file name in root directory.
F1
R
R
R
O
Recovery file not found.
F2
R
R
O
R
Start reading FAT table and analyze FAT to find the clusters
occupied by the recovery file.
occupied by the recovery file.
F3
R
R
O
O
Start reading the recovery file cluster by cluster.
F5
R
O
R
O
Disable L1 cache.
FA
O
R
O
R
Check the validity of the recovery file configuration to the current
configuration of the flash part.
configuration of the flash part.
FB
O
R
O
O
Make flash write-enabled through chipset and OEM-specific
method. Detect correct flash part. Verify that the found flash part
size equals the recovery file size.
method. Detect correct flash part. Verify that the found flash part
size equals the recovery file size.
F4
R
O
R
R
The recovery file size does not equal the found flash part size.
FC
O
O
R
R
Erase the flash part.
FD
O
O
R
O
Program the flash part.
FF
O
O
O
O
The flash has been updated successfully. Make flash
write-disabled. Disable ATAPI hardware. Restore CPUID value
back into register. Give control to F000 ROM at F000:FFF0h.
write-disabled. Disable ATAPI hardware. Restore CPUID value
back into register. Give control to F000 ROM at F000:FFF0h.
Check
point
point
Diagnostic LED decoder
G=Green, R=Red, O=Orange
G=Green, R=Red, O=Orange
Description