CiA402 profile
 
Stop commands:
The "Halt" command enables movement to be interrupted without having to leave the "5 - Operation enabled" state. The stop is performed 
in accordance with the 
[Type of stop]
 
(Stt)
 parameter.
In the case of an open-loop drive, if the "Halt" command is active, no power is supplied to the motor and no torque is applied.
In the case of a closed-loop drive, if the "Halt" command is active, power continues to be supplied to the motor and torque is applied during 
stopping.
Regardless of the assignment of the 
[Type of stop]
 
(Stt)
 parameter (
[Fast stop]
 (FSt)
,
 
[Ramp stop]
 (rMP)
,
 
[Freewheel]
 (nSt)
,
 
[DC injection]
(dCI)
), the drive remains in the "5 - Operation enabled" state.
A Fast Stop command at the terminals or using a bit of the control word assigned to Fast Stop causes a change to the "4 - Switched on" 
state. A "Halt" command does not cause this transition.
A Freewheel Stop command at the terminals or using a bit of the control word assigned to Freewheel Stop causes a change to the "2 - 
Switch on disabled" state.
Assigning control word bits
In the CiA402 profile, fixed assignment of a function input is possible using the following codes:
For example, to assign the DC injection braking to bit 13 of CANopen, simply configure the 
[DC injection assign.] 
(dCI)
 
parameter with 
the
 [C213] 
(C213)
 value.
Bit 11 is assigned by default to the operating direction command 
 [Reverse assign.] 
 
(rrS)
.
 
WARNING
RISK OF EQUIPMENT DAMAGE
When the braking loop is configured, it is necessary to use the "Halt" command (bit 8 of CMD command word) to stop.
Failure to follow these instructions can result in death, serious injury or equipment damage.
Bit
Integrated Modbus
CANopen
Network card
"Controller Inside" card
bit 11
C111
C211
C311
C411
bit 12
C112
C212
C312
C412
bit 13
C113
C213
C313
C413
bit 14
C114
C214
C314
C414
bit 15
C115
C215
C315
C415