Schneider Electric 61 Manual De Usuario
Parameter set switching
68
CHA1 and CHA2 assignment values
Note: In [I/O profile] (IO) configuration, LI1 cannot be accessed and if
[2/3 wire control]
(tCC)
=
[3 wire]
(3C)
, LI2, C101, C201, C301
and C401 cannot be accessed either.
Value
Assignment
Description/Condition
0
[No]
(nO)
Not assigned
4
[Freq. Th. attain.]
(FtA)
Switching via
[Freq. threshold]
(Ftd)
13
[FreqTh.att.2]
(F2A)
Switching via
[Freq. threshold 2]
(F2d)
129
to
134
[LI1]
(LI1)
to
[LI6]
(LI6)
Logic inputs
Drive with or without option
135
to
138
[LI7]
(LI7)
to
[LI10]
(LI10)
Logic inputs
With VW3A3201 logic I/O card
139
to
142
[LI11]
(LI11)
to
[LI14]
(LI14)
Logic inputs
With VW3A3202 extended I/O card
160
to
170
[CD00]
(Cd00)
to
[CD10]
(Cd10)
Switchable bit
In [I/O profile] (IO) configuration
171
to
175
[CD11]
(Cd11)
to
[CD15]
(Cd15)
Switchable bit
Regardless of configuration
177
to
186
[C101]
(C101)
to
[C110]
(C110)
Control bit
With integrated Modbus in [I/O profile] (IO) configuration
187
to
191
[C111]
(C111)
to
[C115]
(C115)
Control bit
With integrated Modbus regardless of configuration
193
to
202
[C201]
(C201)
to
[C210]
(C210)
Control bit
With integrated CANopen in [I/O profile] (IO) configuration
203
to
207
[C211]
(C211)
to
[C215]
(C215)
Control bit
With integrated CANopen regardless of configuration
209
to
218
[C301]
(C301)
to
[C310]
(C310)
Control bit
With a communication card in [I/O profile] (IO) configuration
219
to
223
[C311]
(C311)
to
[C315]
(C315)
Control bit
With a communication card regardless of configuration
225
to
234
[C401]
(C401)
to
[C410]
(C410)
Control bit
With Controller Inside card in [I/O profile] (IO) configuration
235
to
239
[C411]
(C411)
to
[C415]
(C415)
Control bit
With Controller Inside card regardless of configuration