Schneider Electric 61 Manual De Usuario
Configuration saving and switching
66
Function parameters
Code
Description
SCS
Parameter name:
Save configuration
Logic address:
8001 = 16#1F41
Type:
WORD (listing)
CANopen index:
2032/2
Read/write:
R/WS
INTERBUS index:
5FBC/9A
DeviceNet path:
9C/01/9A
0 = No save
1 = Save to configuration no. 0
2 = Save to configuration no. 1
3 = Save to configuration no. 2
1 = Save to configuration no. 0
2 = Save to configuration no. 1
3 = Save to configuration no. 2
FCS
Parameter name:
Restore configuration
Logic address:
8002 = 16#1F42
Type:
WORD (listing)
CANopen index:
2032/3
Read/write:
R/WS
INTERBUS index:
5FBC/9B
DeviceNet path:
9C/01/9B
0 = No restore
1 = Restore configuration no. 0
2 = Restore configuration no. 1
3 = Restore configuration no. 2
1 = Restore configuration no. 0
2 = Restore configuration no. 1
3 = Restore configuration no. 2
64 = Factory setting
FrY
Parameter name:
Parameter groups
Terminal display:
[PARAMETER GROUP LIST]
Logic address:
3022 = 16#OBCE
Type:
WORD (bit register)
CANopen index:
2000/17
Read/write:
R/WS
INTERBUS index:
5FBC/06
Factory setting:
0
DeviceNet path:
70/01/17
Selection of menus to be loaded
bit 0: = 1:
[All]
(ALL)
: All parameters
bit 1: = 1:
[Drive menu]
(drM)
: The [1 DRIVE MENU] menu without [1.9 COMMUNICATION] and [1.14 CONTROL
INSIDE MENU]. In the [7 DISPLAY CONFIG.]
menu,
[Return std name]
returns to
[No]
bit 2: = 1:
[Settings]
(SEt)
: The [1.3 SETTINGS] menu without the
[IR compensation]
(UFr)
,
[Slip compensation]
(SLP)
and
[Mot. therm. current]
(ItH)
parameters
bit 3: = 1:
[Motor param]
(MOt)
: Motor parameters:
[Rated motor power]
(nPr)
-
[Rated motor volt.]
(UnS)
-
[Rated mot. current]
(nCr)
-
[Rated motor freq.]
(FrS)
-
[Rated motor speed]
(nSP)
-
[Auto tuning]
(tUn)
-
[Auto tuning state]
(tUS)
-
[U0]
(U0)
to
[U5]
(U5) -
[F1]
(F1)
to
[F5]
(F5) -
[V. constant power]
(UCP) -
[Freq. Const Power]
(FCP) -
[Nominal I sync.]
(nCrS) -
[Nom motor
spdsync]
(nSPS) -
[Pole pairs]
(PPnS) -
[Syn. EMF constant]
(PHS) -
[Autotune L d-axis]
(LdS) -
[Autotune L q-
axis]
(LqS) -
[Cust. stator R syn]
(rSAS) -
[IR compensation]
(UFr) -
[Slip compensation]
(SLP) -
the motor
parameters that can be accessed in
[Expert]
mode
The following options can only be accessed if
[Config. Source]
(FCSI)
=
[Macro-Conf]
(InI)
:
bit 4: = 1:
[Comm. menu]
(COM)
: The [1.9 COMMUNICATION] menu without either
[Scan. IN1 address]
(nMA1)
to
[Scan. IN8 address]
(nMA8)
or
[Scan.Out1 address]
(nCA1)
to
[Scan.Out8 address]
(nCA8)
bit 5: = 1:
[Control Inside menu]
(PLC)
: The [1.14 CONTROL INSIDE MENU] menu
bit 6: = 1:
[Monitor config.]
(MOn)
: The [6 MONITORING CONFIG.] menu
bit 7: = 1:
[Display config.]
(dIS)
: The [7 DISPLAY CONFIG.] menu
bits 8 to 15: Reserved (= 0 or 1)