LAN Link Problem Descriptions
This section describes problems that can occur with the LAN link between the
DEFINITY G3PD and the DEFINITY LAN Gateway, and suggests possible
solutions to these problems.
DEFINITY G3PD and the DEFINITY LAN Gateway, and suggests possible
solutions to these problems.
NOTE:
In general, the
ping
and
netstat
commands are useful for
troubleshooting problems with a LAN link.
LAN Link Will Not Initialize
Use the DEFINITY G3PD Administrator utility’s Link Status command to check the
status of the link. See ‘‘Link Status Command’’ section in Chapter 3. A link status
of "
status of the link. See ‘‘Link Status Command’’ section in Chapter 3. A link status
of "
Not Initialized
" indicates that link initialization has failed.
This means that the G3PD cannot complete its internal setup or cannot initially
complete the TCP/IP connection with the DEFINITY LAN Gateway.
complete the TCP/IP connection with the DEFINITY LAN Gateway.
Check the IP addresses on the G3PD Configuration screen and on the DEFINITY
LAN Gateway.
LAN Gateway.
To verify that TCP/IP connectivity can be established between the Tserver and the
DEFINITY LAN Gateway, use the
DEFINITY LAN Gateway, use the
ping
command and utility provided for
Windows NT and with the DEFINITY LAN Gateway. The
ping
command will
indicate whether it is possible to reach the DEFINITY LAN Gateway application
from the Tserver. If not, proceed with the following steps:
from the Tserver. If not, proceed with the following steps:
1. Check the configuration of the CTI link on the DEFINITY ECS G3.
Compare the parameter values from the
display station
command
and verify that they are consistent with the required values specified in the
table titled "CTI Link Settings" in Appendix B of Avaya Computer Telephony
Installation Guide.
table titled "CTI Link Settings" in Appendix B of Avaya Computer Telephony
Installation Guide.
2. Check the physical wiring between the Network Interface Card (NIC) for
the G3PD and the DEFINITY LAN Gateway.
3. Check the link integrity setting of the Ethernet cards and hubs.
Also, the Windows NT
netstat
command reports can be used to provide NT
active connections and their connection state. The Local Host ID and Local Port
fields provided in the DEFINITY G3PD Administrator utility’s Link Status command
screen (see Figure 3-6) can be used to locate the corresponding table entry in the
NT
fields provided in the DEFINITY G3PD Administrator utility’s Link Status command
screen (see Figure 3-6) can be used to locate the corresponding table entry in the
NT
netstat
results report. For information on these fields, see Local Host ID and
Local Port in Chapter 3.
After resolving any networking problems, you will have to unload and reload the
G3PD.DLL to initialize the link.
G3PD.DLL to initialize the link.