Adding or Removing Hardware
270 Installation, Upgrades and Additions for Avaya CMC1 Media Gateways
 
Administer the Bus Bridge
1. Type change system-parameters maintenance and press Enter.
2. On Page 2, Type y in the 
PKTINT 2 
field.
3. Choose the port bandwidths or use the default and submit the form.
4. Verify the bus bridge LED is lit on the TN799DP C-LAN circuit pack. This indicates that the 
packet bus is enabled.
Test the Packet Bus and C-LAN Circuit Pack
Type test packet port-network 1 long and press Enter. For more 
detail about these tests, refer to the test pkt command section in the Maintenance for Avaya 
DEFINITY Server CSI
.
Resolve Alarms
Examine the alarm log. Resolve any alarms using Maintenance for Avaya DEFINITY Server 
CSI
.
Enable Alarm Origination to INADS
1. Ask the regional Customer Software Administration to complete the 
 steps. See 
on page 22 for telephone numbers.
Note:
Note:
As part of the system registration process, the INADS Database Administrator 
enables Alarm Origination and customer options.
Verify Customer Options
To verify customer options:
1. Type display system-parameters customer-options and press Enter.
Ensure that the 
G3 version
 field is V11.
2. If the customer was using Supplementary Services Protocol b or d on an ISDN-PRI trunk 
group before the upgrade, go to the QSIG Optional Features screen and ensure that the 
Basic Call Setup
 field is y.