Carrier Access Access Navigator Manual De Usuario

Descargar
Página de 704
6-42
August 2003
Access Navigator - Release 1.8
Electrical Installation
Verify RS-232 Management Connection
Verify RS-232 Management Connection
NOTE:  
Security – No names or passwords are required for new installation and initial 
turn up. The Access Navigator will accept any user, until password security is turned on.
NOTE:  
Command Line Interface – The Access Navigator operating system provides a 
Command Line Interface (CLI), which uses simple text based commands and messages. 
See Command Line Interface Conventions on 
 for a short description of the 
conventions used in this manual to represent management commands, settings, and 
messages. For additional information, see CLI Language Reference on 
1. Turn on power to computer, craft terminal, and optional modem (if used).
2. Configure computer terminal emulation software, or craft terminal, as follows:
Terminal emulation: ANSI, ASCII, VT100
Flow control: None
Send mode: echo characters locally
Baud rate: 9600
Data bits: 8
Parity: None
Stop bits: 1
NOTE:  
In the following step, it is only important that the Access Navigator respond with 
a message. A typical message includes the name of the unit, the time and date, and a 
prompt.
3. Initiate RS-232 management session by pressing keyboard Enter or Return key.
Carrier Access Corporation Access Navigator
08:30:45 01/30/1999
Access Navigator>
Requirement:
Access Navigator message appears on computer or craft terminal display.
NOTE:  
If there is no response from the Access Navigator, refer to Diagnostics & 
.