Carrier Access Access Navigator Manual De Usuario

Descargar
Página de 704
15-48
August 2003
Access Navigator - Release 1.8
Diagnostics & Troubleshooting
Send DS1 Line Pattern with BER Test
    08:15:49   FBE:0      BE:0       CRC:0      BPV/LCV:0
    08:15:50   FBE:0      BE:0       CRC:0      BPV/LCV:0
    08:15:51   FBE:0      BE:0       CRC:0      BPV/LCV:0
    08:15:52   FBE:0      BE:0       CRC:0      BPV/LCV:0
    08:15:53   FBE:0      BE:0       CRC:0      BPV/LCV:0
    08:15:54   FBE:0      BE:0       CRC:0      BPV/LCV:0
    08:15:55   FBE:0      BE:0       CRC:0      BPV/LCV:0
    08:15:56   FBE:0      BE:0       CRC:0      BPV/LCV:0
              Totals        Error Rates
   FBE:       0             0.000000e+00
   BE:        0             0.000000e+00
   CRC:       0             0.000000e+00
   LCV/BPV:   0             0.000000e+00
   Signaling done.
The following error message will occur if an incorrect pattern is received:
Message:
Waiting for pattern sync.........no sync.
The following error message will occur if there is no loopback in effect:
Message:
*-Unable to send code;
*- far-end is not in loopback.
Description:
Item
Description
Time
Time is recorded in one-second intervals. Format is 24-hour 
clock in hours:minutes:seconds with colons to separate the digits, 
as in 08:30:45 and 15:22:10.
FBE
Number of Frame Bit Errors (4095 maximum) in one-second 
interval.
BE
Number of Bit Errors (4095 maximum) in one-second interval
CRC
Number of Cyclical Redundancy Check errors (1023 maximum) 
in one-second interval
BPV/LCV
Number of Bi-Polar Violations and Line Code Violations 
(16,383 maximum) in one-second interval
Totals
Total number of errors for 10-second test interval
Error Rates
Total error rates measured during the 10-second test interval, 
expressed in scientific notation where "e" indicates a power of 
10. For example, 1 error per 1.544 megabits is 6.520000e-07. 
The maximum value is 2.700000e-03.