Diagnostics & Troubleshooting
Send DS1 Payload Pattern with BER Test
Syntax:
send ds1 <n> payload 
<allones|allzeros|f1in8|p2e11|p2e15|p2e23|qrsstest
Example:
send ds1 9 payload p2e15 test
For most patterns, the CLI will provide a progress message indicating the success (ok) 
or failure of the command followed by the test results, as in the following samples.
Message:
Waiting for pattern sync........ok.
   Testing line...
    08:15:47   FBE:0      BE:0       CRC:0      BPV/LCV:0
    08:15:48   FBE:0      BE:0       CRC:0      BPV/LCV:0
    08:15:49   FBE:0      BE:0       CRC:0      BPV/LCV:0
    08:15:50   FBE:0      BE:0       CRC:0      BPV/LCV:0
    08:15:51   FBE:0      BE:0       CRC:0      BPV/LCV:0
    08:15:52   FBE:0      BE:0       CRC:0      BPV/LCV:0
    08:15:54   FBE:0      BE:0       CRC:0      BPV/LCV:0
    08:15:55   FBE:0      BE:0       CRC:0      BPV/LCV:0
Field
Description
n
DS1 number, 1 to 32, or a range of numbers such as 2-8.
allones
Send framed all-ones pattern. This can be used as a “keep alive” 
signal, idle code, and in measuring the T1 power level.
allzeros
Send framed all-zeros pattern. This can be used to test T1 circuits 
for B8ZS clear channel capability and to find equipment 
incorrectly set to AMI line code.
Note: When using an all-zeros pattern, a T1 test set (such as a 
T-Berd 224 or Sunset T3)  must be used to monitor for errors in 
the all-zeros pattern from the Access Navigator or looped back 
from a far-end network element.
f1in8
Send framed 1-in-8 pattern (also called a 1-and-7 pattern) in 
which each payload byte contains the bit pattern 01000000. 
(Minimal ones density test for T1 circuits with AMI coding.) 
Note: You must wait 30 seconds after the prompt appears before 
doing another test.
p2e11
Send 2
11
–1 pattern with a maximum of 10 consecutive zeros and 
11 consecutive ones. (Minimum stress testing.)
p2e15
Send 2
15
–1 pattern with a maximum of 14 consecutive zeros and 
15 consecutive ones. (Provides maximum number of consecutive 
zeros permissible in framed, non-B8ZS testing.)
p2e23
Send 2
23
–1 pattern with a maximum of 22 consecutive zeros and 
23 consecutive ones. (Maximum stress testing.)
qrss
Send QRSS pattern (a modified 2
20
–1) with a maximum of 14 
consecutive zeros and 20 consecutive ones. (Common stress test 
for T1 data applications.)