Broadmore 1750 - Release 4.6
7-25
 Configuration
Module Redundancy
Module Redundancy
Protection Definitions
Automatic protection switching (APS) is performed in accordance with specifications 
except as noted. The following definitions are provided to clarify the terms used in 
NIM redundancy.
Item
Definition
APS
Automatic Protection Switching
Reverting
After redundancy switching, the system will switch back to 
the original primary NIM when repairs are completed.
Non-
reverting
After redundancy switching, the protection NIM will 
remain the system primary NIM after repairs are completed. 
In this case, the repaired NIM becomes the protection NIM. 
This only applies to manual switching.
1+1 
Protection
The signal is continuously bridged to the working and 
protection equipment so payloads are transmitted 
identically over both paths. The receiving equipment 
chooses either path. The user must set their equipment to bi-
directional. The Broadmore 1750 supports bi-directional 
1+1 APS for the NIM. The Broadmore 1750 does not 
support uni-directional 1+1 APS for the NIM.
1:n 
Protection
There is one backup for n critical components. Any of the n 
working channels can be bridged to a single protection line.