Carrier Access CMG Router Manual De Usuario
11-2
CMG Router - Release 2.7
Router Configuration
Installation
Installation
Installation of the CMG Router card into the Adit 600 chassis.
Unit can be on or off
CMG Router card will work in any slot
Slide card into slot until fully seated
CMG Router has completed it’s boot cycle when CRD light is solid
CMG Router card will work in any slot
Slide card into slot until fully seated
CMG Router has completed it’s boot cycle when CRD light is solid
The following setups are all executed with CLI
NOTE: Configuration can be done with the following CLI commands or with
the Router Menu-Driven Software.
the Router Menu-Driven Software.
Basic Setup
Command
Description
set {ds0-addr} type data
Confirm DS0 is set to type data.
ds0-addr = {slot:port:channel} of DS0
Example: set a:1:1-24 type data
ds0-addr = {slot:port:channel} of DS0
Example: set a:1:1-24 type data
connect {slot:port:trunk}
{slot:port:channel}
{slot:port:channel}
Cross-connect T1 to router card.
Example: connect a:1:1-24 6:1:1 (router in slot 6)
Example: connect a:1:1-24 6:1:1 (router in slot 6)
set {router-addr} proxy
Disable/enable router proxy.
router-addr = {slot:port}| of router card.
Example: set 6:1 disable.
router-addr = {slot:port}| of router card.
Example: set 6:1 disable.
set {slot:port} up
Set Router LAN as In-Service. Example: set 6:1 up
telnet {router_card-addr}
Telnet to Router card.
router_card-addr = {slot} location of router card
Example: telnet 6 (if earlier than 3.0 release {slot:port} must
be used)
router_card-addr = {slot} location of router card
Example: telnet 6 (if earlier than 3.0 release {slot:port} must
be used)
Local and Remote Profile Setup
reinitialize
To enable any configuration changes, the card must be
reinitialized.
reinitialized.