3com 5102B-EE Manual De Usuario

Descargar
Página de 246
Firmware Download Instructions 6 - 17
Bridge Module Problems
Bridge Module problems during the download cause an error statement to 
be displayed on the screen. Common error messages and their meanings 
are discussed in Table 6-2.
Fatal Error: Insufficient 
Available Memory to run 
ProComm
A minimum of 200k bytes of free 
memory is necessary to successfully 
run ProComm and to do the 
download. Decreasing the number of 
Terminate and Stay Resident Programs 
present while running the UDK 
program will free memory.
Fatal Error: Unable to run 
ProComm or ProComm not 
found
The ProComm subdirectory on the 
destination drive either does not 
contain ProComm or ProComm has 
been corrupted. Verify that the 
ProComm files exist on the destination 
drive in the subdirectory \PROCOMM.
Table 6-2.  Bridge Module Download Error Messages
Problem
Troubleshooting Suggestion
Maximum bad CRC
Check RS-232 cable and retry. If the 
problem persists, call 3Com Support.
Max timeouts
User did not start the download quickly 
enough, try again.
Incorrect  code  type
Check that you used the correct diskette 
and try again. If the problem persists, 
call 3Com Support.
Table 6-1.  UDK Error Messages (Continued)
Message
Troubleshooting Suggestion