2 - 14 ONline Ethernet Bridge Module Installation and Operation Guide
Once you have configured your terminal to match the factory defaults of 
the Bridge Module, you can connect a cable from the terminal to the 
RS-232 port on the Bridge Module.
Connecting to the Bridge Module RS-232 Port
The RS-232 cable connects to the management interface on the Bridge 
Module front panel.  Table 2-6 defines general cabling guidelines that apply 
for connecting various devices to the management interface..
Note: The 3Com Firmware Distribution Kit (5000-FDK) provides a 
cable for connection to a PC or terminal.
Appendix C describes the proper pinouts for male-to-female, crossover 
RS-232 cable.
Connecting the Transceiver Cable
This section explains how to connect the transceiver cable to the AUI port 
on the Bridge Module.  If you do not intend to use the AUI port to connect 
to a subnetwork, skip this section.
To install the transceiver cable, follow these steps while referring to 
Figure 2-5:
1. Push the slide latch to the up position.
Table 2-6.  RS-232 Cable Guidelines
Device
Cable
Terminal
Female-to-female crossover 
Female-to-male crossover
Modem
Male-to-female straight-through
Terminal Server
Refer to Supplier Documentation