Viewsonic PJ1065 Manual De Usuario

Descargar
Página de 30
20
ViewSonic  PJ1065
TROUBLESHOOTING
OSD Message
The messages as described below may appear on the screen at power ON. Take the appropriate mea-
sures when such messages appear.
Table 9: OSD Message
NOTE: 
(*1) This message is cleared automatically after approximately three minutes, and appears every 
time power is switched ON.
(*2) The unit has a function to turn the power off which will be active when the usage time reaches 
2000 hr. However the life of lamp might be much different, so that it might happen that a lamp is cut 
off before the function is active.
Message
Contents
CHANGE THE LAMP
AFTER REPLACING LAMP,
RESET THE LAMP TIME.
(*
1)
The usage time of lamp will be reaching 2000 hr shortly (*2).
It is recommended to replace the lamp soon. Prepare a new lamp 
as replacement.
CHANGE THE LAMP
AFTER REPLACING LAMP,
RESET THE LAMP TIME.
THE POWER WILL TURN 
OFF
AFTER **hr.
(*
1)
The usage time of lamp will be reaching 2000 hr shortly.
It is recommended to replace the lamp within * * hours (*2).
It might happen that the lamp is cut off before * * hr by any 
chance. Power will be switched OFF automatically in * * hours. 
Replace the lamp as shown on p. 17-18, “Lamp.” Always reset 
the lamp timer after replacing the lamp.
CHANGE THE LAMP
AFTER REPLACING LAMP,
RESET THE LAMP TIME.
THE POWER WILL
TURN OFF
AFTER 0 hr.
The usage time of lamp is about to reach. Power will be switched 
OFF in a few minutes (*2).
Switch power OFF immediately and replace the lamp as shown 
on p. 17-18, “Lamp.” Always reset the lamp timer after replacing 
the lamp.
NO INPUT IS DETECTED
ON ***
No input signal found.
Check the signal input connections and signal sources.
SYNC IS OUT OF RANGE
ON ***
The horizontal or vertical frequency of the input signal is not 
within the specified range.
Check the specifications of the equipment and the signal source.
CHECK THE AIR FLOW
The internal temperature has risen.
Switch power OFF, and wait 20 minutes until the equipment cools 
down.
Check the following and Switch power ON again.
* Are the ventilation openings blocked.
* Is the air filter dirty.
* Is the ambient temperature higher than 35°C.