Citizen Systems PMU2XXX Manual De Usuario

Descargar
Página de 312
 
- 287 - 
4.2.5 MSW5 
MSW5-1: Buzzer 
[Outline]  Select the enable/disable of buzzer.
 
 
 
OFF(0) ON(1) 
Buzzer Valid Invalid 
 
ON (1) OPERATION: Disable buzzer 
When an error occurs or memory switch setting is changed manually, no buzzer sounds. 
OFF (0) OPERATION: Enable buzzer. 
When an error occurs or memory switch setting is changed manually, the buzzer sounds. 
 
 
MSW5-2:  Basic vertical calculation pitch 
[Outline]  Select the basic calculation pitch in the paper feed direction.
 
 
 
OFF(0) ON(1) 
Line Pitch 
360 
406 
 
ON (1) OPERATION: Basic vertical calculation pitch is set to 1/406 inch. 
Line-feed length is 3.75mm by default. 
OFF (0) OPERATION: Basic vertical calculation pitch is set to 1/360 inch. 
Line-feed length is 4.23mm by default. 
 
 
MSW5-3: USB mode 
[Outline] Select 
USB 
mode.
 
 
 
OFF(0) ON(1) 
USB Mode 
Virtual COM 
Printer Class 
 
ON (1) OPERATION: Operated as Printer class 
OFF (0) OPERATION: Operated as virtual COM class
   
 
 
MSW5-4:  Reserved [Fixed to OFF (0)]