Citizen Systems PMU2XXX Manual De Usuario

Descargar
Página de 312
 
- 289 - 
4.2.7 MSW7 
MSW7-1: Baud rate 
[Outline]  Select baud rate which is serial interface communication condition. 
Enabled if DSW1-1 OFF is set [following memory switch setting].
 
 
 
Setting Value 
Baud Rate 
1200bps,2400bps,4800bps,9600bps,19200bps, 
38400bps,57600bps,115200bps 
 
 
MSW7-2: Data length 
[Outline]  Select the data length, which is a serial interface communication condition. 
Enabled if DSW1-1 OFF is set [following memory switch setting]. 
 
 
Setting Value 
Data Length 
7bits,8bits 
 
 
MSW7-3: Stop bit 
[Outline]  Select the stop bit, which is a serial interface communication condition. 
Enabled if DSW1-1 OFF is set [following memory switch setting]. 
 
 
Setting Value 
Stop Bit 
1bit,2bits 
 
 
MSW7-4: Parity 
[Outline]  Select the parity, which is a serial interface communication condition. 
Enabled if DSW1-1 OFF is set [following memory switch setting]. 
 
 
Setting Value 
Parity NONE, 
ODD, 
EVEN 
 
 
MSW7-5: Busy control 
[Outline]  Select the busy control, which is a serial interface communication condition. 
Enabled if DSW1-1 OFF is set [following memory switch setting]. 
 
 
Setting Value 
Flow Control 
DTR/DSR, XON/XOFF