GS ^ n1 n2 n3 
CT-S280 
CT-S300 
CT-S2000
CT-S4000
BD2-2220 
CT-S310 
support model 
PMU2XXX 
     
 
 
[Function] 
Executing the macro
 
 
[Code] 
<
1D>H<5E>H<n1><n2><n3> 
 
[Range] 
0≦n1≦255 
0≦n2≦255 
0≦n3≦1 
 
[Outline] 
[The specification which is common to the model]
 
Executing contents defined in macro. 
n1 : The number of times of macro execution 
n2 : Waiting time on macro execution: Waiting time of n2 x 100 msec is given for every execution. 
n3 : Macro execution mode 
n3 = 0 Continuous execution:   The Macro is executed “n1” times continuously at the time 
interval specified by “n2”. 
n3 = 1 Execution by FEED Switch:   After waiting for the time specified by “n2”, the ARARM LED 
flickers and the FEED switch is waiting to be pressed. When 
it is pressed, the macro is executed once. This action is 
repeated “n1” times. 
 
[Caution]
 
• When this command is received while in macro definition, suspension of macro definition is 
indicated. At this time, the defined content is cleared. 
• No execution takes place when the macro is held undefined. 
• While in macro execution with n3 = 1, paper feed with the FEED switch is not available. 
 
[See Also]
 
 