Citizen Systems BD2-2220 用户手册
- 99 -
GS ^ n1 n2 n3
CT-S280
CT-S300
CT-S2000
CT-S4000
BD2-2220
CT-S310
support model
PMU2XXX
[Function]
Executing the macro
[Code]
<
1D>H<5E>H<n1><n2><n3>
[Range]
0≦n1≦255
0≦n2≦255
0≦n3≦1
0≦n3≦1
[Outline]
[The specification which is common to the model]
Executing contents defined in macro.
n1 : The number of times of macro execution
n2 : Waiting time on macro execution: Waiting time of n2 x 100 msec is given for every execution.
n3 : Macro execution mode
n1 : The number of times of macro execution
n2 : Waiting time on macro execution: Waiting time of n2 x 100 msec is given for every execution.
n3 : Macro execution mode
n3 = 0 Continuous execution: The Macro is executed “n1” times continuously at the time
interval specified by “n2”.
n3 = 1 Execution by FEED Switch: After waiting for the time specified by “n2”, the ARARM LED
flickers and the FEED switch is waiting to be pressed. When
it is pressed, the macro is executed once. This action is
repeated “n1” times.
it is pressed, the macro is executed once. This action is
repeated “n1” times.
[Caution]
• When this command is received while in macro definition, suspension of macro definition is
indicated. At this time, the defined content is cleared.
• No execution takes place when the macro is held undefined.
• While in macro execution with n3 = 1, paper feed with the FEED switch is not available.
• While in macro execution with n3 = 1, paper feed with the FEED switch is not available.
[See Also]
[Sample Program]