Cino MP3200 Manual De Usuario
Command Descriptions
Programming Reference
VERSAJET MP3200
GS ( k RSS-14<Function 881>
[Format]
ASCII
GS ( k pL pH cn fn m
Hex
1D 28 6B 03 00 38 51 m
Decimal
29 40 107 03 00 56 81 m
[Range] (pL + pH x ҏ256) = 3 (pL = 3, pH = 0 )
cn = 56
fn = 81
m = 48
fn = 81
m = 48
[Default] None
[Description]
Encodes and prints the RSS-14 symbol data in the symbol save area.
[Notes]
If there is any error described below in the data of the symbol save area, it cannot be
printed.
printed.
There is no data (Function 880 is not processed).
If the data of the symbol save area is more than the data allowed by specified model
and data compaction mode.
and data compaction mode.
This command is effective only in Page mode.
153