Cino MP3200 Manual De Usuario

Descargar
Página de 196
Command Descriptions 
Programming Reference
VERSAJET MP3200
For JAN8/EAN8 (m = 3, 68) process 
‹
Modular check character is processed as follows: 
„
Automatically added when processing data is 7 byte. 
„
The 8th byte data is processed as a modular check character when processing data is 
8 byte. In this case, modular check character is not checked. 
‹
Left guard bar/center bar/right guard bar are added automatically.
For CODE39 (m = 4, 69) process 
‹
The printer processes the start code (ASCII = */ Hex = 2Ah/Decimal = 42) as follows: 
„
When the first bar code (d1) is “*”, the printer processes the data as a first character.
„
If the first bar code (d1) is not “*”, the printer adds a start character (*) automatically.
‹
The printer processes the start code (ASCII = */ Hex = 2Ah/Decimal = 42) as follows: 
„
When the last bar code (dk or dn) is “*”, the printer processes the data as a last 
character.
„
If the last bar code (dk or dn) is not “*”, the printer adds a last character (*)
automatically.
„
When “*” is processed during bar code data processing, the printer processes “*” as a 
stop character. The printer prints data preceding “*” and finishes command processing.
Therefore, data following “*” are processed as normal data.
‹
Check digits are not calculated and added. 
167
Preliminary Rev. 02