236
 
RS/6000 43P 7043 Models 150 and 260 Handbook
To get the information, run the following command
/usr/lpp/diagnostics/bin/uesensor -l
and you will see a output similar to the this:
The status of the environmental sensors can also be shown by using the 
diagnostics service aid. To start diagnostics, enter: 
diag
8.5  Network Boot Support
If you are booting over the network, follow these steps:
1. Begin with your machine turned off or shut down your system properly if it 
is already running.
2. Power on the machine and enter the System Management Services (SMS) 
by pressing the F1 key.
3. The SMS menu displays on your screen. Select the Utilities option.
4. From the System Management Services Utilities menu, select the Remote 
Initial Program Load (RIPL) option.
5. From the screen, select the Set Address option.
6. Set or change the values displayed so they are correct for your client 
system.
Specify the IP address of:
  • The client machine you are booting in the 
client address
 field.
Sensor = Fan Speed 
Status = Normal 
Value = 2436 RPM 
Location Code = F1 
Sensor = Power Supply 
Status = Normal 
Value = Present and operational 
Location Code = V1 
Sensor = Power Supply 
*Status = Critical low 
Value = Present and not operational 
Location Code = V2