IBM 6059 Manual De Usuario

Descargar
Página de 248
Diagnostic Error Code
FRU/Action
000-038-XXX
BIOS Extension failure
1.
Flash the system
2.
Adapter card
3.
System board
000-039-XXX
BIOS DMI data error
1.
Flash the system
2.
System board
000-195-XXX
BIOS Test aborted by user
1.
Information
2.
Re-start the test, if necessary
000-196-XXX
BIOS test halt, error threshold
exceeded
1.
Press F3 to review the log file
2.
Re-start the test to reset the log file
000-197-XXX
BIOS test warning
1.
Make sure the component that is called out is
connected and/or enabled
2.
Re-run test
3.
Component that is called out in warning statement
4.
Component under test
000-198-XXX
BIOS test aborted
1.
If a component is called out, make sure it is
connected and/or enabled
2.
Flash the system and re-test
3.
Go to the
″Undetermined problems″ section
000-199-XXX
BIOS test failed, cause unknown
1.
Go to the
Undetermined problems″ section
2.
Flash the system and re-test
3.
Replace component under function test
000-250-XXX
BIOS APM failure
1.
Flash the system
2.
System board
000-270-XXX
BIOS ACPI failure
1.
Flash the system
2.
System board
001-000-XXX
System Test Passed
1.
No action
001-00X-XXX
System Error
1.
System board
001-01X-XXX
System Error
1.
System board
001-024-XXX
System Addressing test failure
1.
System board
001-025-XXX
System Checksum Value error
1.
Flash the system
2.
System board
001-026-XXX
System FLASH data error
1.
Flash the system
2.
System board
2
Hardware Maintenance Manual: IBM NetVista Computer Types 6058, 6059, 6269, 6568, 6569, 6578, 6579, 6648,
6649