Diagnostic Error Code
FRU/Action
001-027-XXX
System Configuration/Setup error 1. Run Setup
2.
Flash the system
3.
System board
001-032-XXX
System Device Controller failure
1.
System board
001-034-XXX
System Device Buffer Allocation
failure
1.
Reboot the system
2.
Flash the system
3.
Run memory test
4.
System board
001-035-XXX
System Device Reset condition
detected
1.
System board
001-036-XXX
System Register error
1.
System board
001-038-XXX
System Extension failure
1.
Adapter card
2.
System board
001-039-XXX
System DMI data structure error
1.
Flash the system
2.
System board
001-040-XXX
System IRQ failure
1.
Power-off/on system and re-test
2.
System board
001-041-XXX
System DMA failure
1.
Power-off/on system and re-test
2.
System board
001-195-XXX
System Test aborted by user
1.
Information
2.
Re-start the test, if necessary
001-196-XXX
System test halt, error threshold
exceeded
1.
Press F3 to review the log file
2.
Re-start the test to reset the log file
001-197-XXX
System test warning
1.
Make sure the component that is called out is
connected and/or enabled
2.
Re-run test
3.
Component that is called out in warning statement
4.
Component under test
001-198-XXX
System test aborted
1.
If a component is called out, make sure it is
connected and/or enabled
2.
Flash the system and re-test
3.
Go to the
″Undetermined problems″ section
Chapter 1. IBM PC Enhanced Diagnostics error codes