•  Enter the IP address, IP mask and default router of the CEN-UPS1250 via 
the Crestron Toolbox (Functions | Ethernet Addressing); otherwise enable 
DHCP. 
•  Confirm Ethernet connections between CEN-UPS1250 and PC. If 
connecting through a hub or router, use CAT5 straight through cables with 
8-pin RJ-45 connectors. Alternatively, use a CAT5 crossover cable to 
connect the two LAN ports directly without using a hub or router. 
•  Use the Address Book in the Crestron Toolbox to create an entry for the 
CEN-UPS1250 with the CEN-UPS1250’s TCP/IP communication 
parameters. 
•  Display the “System Info” window (click the 
 icon) and select the 
CEN-UPS1250 entry. 
Programs and Firmware 
Program or firmware files may be distributed from programmers to installers or from 
Crestron to dealers. Firmware upgrades are available from the Crestron website as 
new features are developed after product releases. One has the option to upload 
programs via the programming software or to upload and upgrade via the Crestron 
Toolbox. For details on uploading and upgrading, refer to the SIMPL Windows help 
file or the Crestron Toolbox help file. 
SIMPL Windows 
  If a SIMPL Windows program is provided, it can be uploaded to the control system 
using SIMPL Windows or Crestron Toolbox. 
Firmware  
Check the Crestron website to find the latest firmware. (New users may be required 
to register to obtain access to certain areas of the site, including the FTP site.) 
Upgrade CEN-UPS1250 firmware via Crestron Toolbox. 
•  Establish communication with the CEN-UPS1250 and display the “System 
Info” window. 
•  Select Functions | Firmware… to upgrade the CEN-UPS1250 firmware. 
Program Checks 
In Crestron Toolbox, display the “System Info window (click the 
 icon) and 
select the Functions menu to display actions that can be performed on the  
CEN-UPS1250. 
Be sure to use the Crestron Toolbox to create the CEN-UPS1250 IP table. 
•  Select Functions | IP Table Setup
•  Add, modify or delete entries in the IP table. The CEN-UPS1250 can have 
only one IP table entry. 
•  A defined IP table can be saved to a file or sent to the device. 
Edit the control system’s IP table to include an entry for the CEN-UPS1250. The 
entry should list the CEN-UPS1250’s IP ID (specified on the CEN-UPS1250’s IP 
table) and the internal gateway IP address 127.0.0.1. 
Operations & Installation Guide – DOC. 6635A 
Uninterruptible Power Supply: CEN-UPS1250  
  21