Xantrex Technology XPH 35-4T Manual De Usuario

Descargar
Página de 37
  
Calibration 
Allow at least 5 minutes warm-up before commencing calibration. 
Access to Calibration Adjustments 
All adjustments are on the front panel control board; all the trimmers are adjusted from the 
reverse side of the board through holes in the board.  To gain access to the board it is necessary 
to remove the top cover. 
WARNING! 
When the instrument is connected to its supply the removal of covers is likely to expose live parts. 
The instrument should be disconnected from all voltage sources before it is opened for any 
adjustment, replacement, maintenance or repair. Capacitors inside the power supply may still be 
charged even if the power supply has been disconnected from all voltage sources but will be 
safely discharged about 5 minutes after switching off power. 
Any adjustment, maintenance and repair of the opened instrument under voltage shall be avoided 
as far as possible and, if inevitable, shall be carried out only by a skilled person who is aware of 
the hazard involved. 
Remove the 6 side screws and the front handle screw to release the top cover. 
Component adjustment references are given as Channel A/ Channel B, e.g. VR5/VR105; 
Channel A is the left-hand output.   
 
 
Control pcb calibration points (viewed from rear) 
Equipment Required 
A 5½ digit multimeter with better than 0·05% accuracy on dc volts and better than 0·1% accuracy 
on dc current (to 5A); alternatively use a precision shunt for current measurement. 
Rheostat or other high power load arrangement to provide up to 5A load at 35V. 
Voltage Calibration 
Connect the DMM (set to Volts) across the output. Set voltage and current controls to minimum. 
Switch output ON (Check LED is on) and check for a reading of 00·0V ± 0·1V on the Volts display 
and DMM; check the Amps display reads 0·00 ± 0·01A. 
Set voltage and current controls to maximum. Adjust VR5/VR105 (maximum output volts) for a 
reading of 35·16V to 35·24V on the DMM. Adjust VR6/VR106 (measured output volts) until the 
Volts display matches the reading on the external DMM. 
Switch output OFF. Adjust VR10/110 (preset volts) until the Volts display shows 35·2. 
 10