Maintenance 
The Manufacturers or their agents overseas will provide repair for any unit developing a fault. 
Where owner wish to undertake their own maintenance work, this should only be done by skilled 
personnel in conjunction with the service manual which may be purchased directly from the 
Manufacturers or their agents overseas. 
Fuse 
The correct fuse type is: 
10 Amp 250V HBC time-lag(T), 5 x 20mm. 
Note that the main function of the fuse is to make the instrument safe and limit damage in the 
event of failure of one of the switching devices. If a fuse fails it is therefore very likely that the 
replacement will also blow, because the supply has developed a fault; in such circumstances the 
instrument will need to be returned to the manufacturer for service. 
Make sure that only fuses of the required rated current and specified type are used for 
replacement. The use of makeshift fuses and the short-circuiting of fuse-holders is prohibited. 
To replace a fuse, first disconnect the instrument from the AC supply. Remove the 7 cover 
securing screws and lift off the cover. Replace the fuse with one of the correct type and refit the 
cover. 
Cleaning 
If the PSU requires cleaning use a cloth that is only lightly dampened with water or a mild 
detergent. Polish the display window with a soft dry cloth. 
WARNING! TO AVOID ELECTRIC SHOCK, OR DAMAGE TO THE PSU, NEVER ALLOW 
WATER TO GET INSIDE THE CASE. TO AVOID DAMAGE TO THE CASE OR DISPLAY 
WINDOW NEVER CLEAN WITH SOLVENTS. 