88 ● ET   
 
 
 
 
 
   DMC-1400 Series Command Reference 
ET  
 
FUNCTION
Electronic cam table 
DESCRIPTION: 
The ET command sets the ECAM table entries for the slave axis.  The values of the master are 
not required.  The slave entry (n) is the position of the slave when the master is at the 
point (n 
∗ i) + o, where i is the interval and o is the offset as determined by the EP 
command. 
ARGUMENTS:  ET [n] = m 
where 
n is an integer between 0 and 256 
m is an integer in the range between -2,147,438,648, and 2,147,438,647 
USAGE
While Moving 
Yes 
Default Value 
 
In a Program 
Yes 
Default Format   
Command Line 
Yes 
 
 
Can be Interrogated 
No 
 
 
Used as an Operand 
No 
 
 
Controller Usage                ALL  
RELATED COMMANDS: 
Enable Ecam 
Engage Ecam 
Specify Ecam Cycle 
Specify Ecam intervals and starting point 
Ecam quit 
EXAMPLES: 
ET [7] = 1000 
Specifies the position of the slave that must be synchronized with the 
eighth increment of the master.